Hey guys,
I have a quick question regarding the replacement of capactors in my MS- and M-series amps. Do I need to replace all the little bitty caps as well as the power supply/rail caps? I have read the threads in the FAQ/How-to section and see no mention of this. I'm trying to figure out what it's going to cost me to re-cap an MS-2125, an MS-275 and an M-100.
Thanks!
NG
MS and M capacitor replacement
Re: MS and M capacitor replacement
i would just do the psu caps unless there is any signs of damage to the rest ie- film shrinkage and leaking or swelling. generally it's just the psu caps that need replacing but it wouldn't harm to swap them all out..
Ti1 headunit (unique)
Outlaw in crate.
2x original shrouded ms2250's.
Route 66 in box + custom m100 to match.
Roadster 66 in flight case
Octane LE in box.
Reactor #186 in flight case.
Reactor EQ232
Ti400.2 AL
AX204A + EQ232 + ZPX2 + TBA set
ZCS6 component set
Tantrum+Titanium bass cubes
Ti12d Elite sub
DD5 + DD10 + 6 Ti blocks!
Outlaw in crate.
2x original shrouded ms2250's.
Route 66 in box + custom m100 to match.
Roadster 66 in flight case
Octane LE in box.
Reactor #186 in flight case.
Reactor EQ232
Ti400.2 AL
AX204A + EQ232 + ZPX2 + TBA set
ZCS6 component set
Tantrum+Titanium bass cubes
Ti12d Elite sub
DD5 + DD10 + 6 Ti blocks!
Re: MS and M capacitor replacement
Thanks. The caps in the M100 are definitely swelling, but no leakage. No leakage in the MS2125 either but I think the big caps are starting to swell. It's hard to tell since they have been covered with a PG sticker/blue plastic wrap.

What you mean by "film shrinkage"?
NG

What you mean by "film shrinkage"?
NG
- HoseHead
- Tim Horton Himself
- Posts: 2262
- Joined: Wed Dec 06, 2006 4:49 pm
- Location: Ottawa, Ontario, Canada
- Contact:
Re: MS and M capacitor replacement
Ever dive into a cold pool? That's shrinkage.
The plastic film around the capacitor shrinks due to prolonged and/or excessive heat. Those look fine but I don't think they're original units for an M. They may have been done already.
Slide a cigarette paper under the cap and check for residue - leakage. It's a good insurance policy to replace them anyway.
HH



The plastic film around the capacitor shrinks due to prolonged and/or excessive heat. Those look fine but I don't think they're original units for an M. They may have been done already.
Slide a cigarette paper under the cap and check for residue - leakage. It's a good insurance policy to replace them anyway.
HH
The only stupid question is the one not asked .......
Re: MS and M capacitor replacement
HH,HoseHead wrote:Ever dive into a cold pool? That's shrinkage.![]()
![]()
![]()
The plastic film around the capacitor shrinks due to prolonged and/or excessive heat. Those look fine but I don't think they're original units for an M. They may have been done already.
Slide a cigarette paper under the cap and check for residue - leakage. It's a good insurance policy to replace them anyway.
HH
These caps are in my MS2125. I've had it for at least 10 years. It looks like just a sticker on the top and some heat-shrink plastic around the body of the cap. I slid some paper under all the caps on all my PG amps, and none are leaking enough to dampen the paper. I did find a few drops of clear liquid around one cap, but couldn't find any more.
NG